| Project Description |
Industry |
Area |
| Reconfiguration and commissioning of Fischer + Porter DCI5000 DCS controlling batch chemical plant. |
Speciality Chemicals |
South West |
| Reverse engineering and replacement of Rosemount Diogenes Process Control System controlling boiler house with current generation DCS. Change-over to the new system was achieved one loop at a time with the plant on-line. |
Food & Beverage |
North West |
| Tidy up of the application configuration and the preparation of a new system documentation package for a Fisher-Rosemount DCS. The documentation package included the detailed specification of a proposed system expansion to accommodate additional process plant. |
Food & Beverage |
North West |
| Replacement of two Wonderware In Touch SCADA systems with Intellution Fix32, including the reverse engineering of the existing In Touch configurations. Y2K upgrade project. |
Food & Beverage |
North West |
| Development of training simulator for RS3 DCS. |
Oil & Gas |
East Anglia |
| Replacement of ageing Bailey Lan 90 PCV DCS consoles with Intellution iFIX-based OPsCon consoles. Y2K upgrade project. |
Speciality Chemicals |
West Midlands |
| Modifications to Intellution Fix32 SCADA System configuration, including re-writing of production line control sequence spread across several "close picture" scripts and overall system optimisation. Supply, installation and configuration of new industrial PC. |
Automotive |
West Midlands |
| Configuration of Fisher-Rosemount DeltaV process control system controlling powder/liquid mixing and granulation plant. |
Speciality Chemicals |
North Wales |
| Co-ordination of Y2K upgrade work for DCS, ESD, F&G systems.
Engineering Support for Fisher-Rosemount RS3 and Bailey I90 DCS. |
Oil & Gas |
East Anglia |
| Configuration of expansion to Fisher-Rosemount RS3 DCS to cater for uprating of anaesthetics batch production plant. |
Pharmaceutical |
South West |
| Supply and configuration of Intellution iFIX-based OPsCon operator console for Bailey I90 DCS. |
Energy from Waste |
West Midlands |
| RS3 DCS configuration services for batch chemicals plants. |
Specialty Chemicals |
East Midlands |
| Design, supply, configuration and commissioning of assembly line barcode monitoring system. The main system components were networked Data Logic barcode scanners, an Allen-Bradley SLC500 PLC and an Intellution iFIX SCADA system. |
Automotive |
West Midlands |
| Supply and installation of 2nd user Bailey Infi Net communications modules and power supplies. |
Energy from Waste |
West Midlands |
| Replacement of individual temperature controllers for vacuum brazing furnaces with a modern Eurotherm Suite control system with integrated operator displays. This project included the reverse engineering of the existing setpoint programmer based system. |
Automotive |
West Midlands |
| Replacement of ageing Bailey Lan 90 PCV DCS consoles with Intellution iFIX-based OPsCon consoles. |
Speciality Chemicals |
North West |
| Co-ordination and provision of Engineering Support for Fisher-Rosemount RS3 DCS, including the supervision of less-experienced 3rd party engineers. |
Oil & Gas |
East Anglia |
| Upgrade of assembly line barcode monitoring system including supply, fitting and configuration of replacement PLC and SCADA system. The final system was similar to a previously supplied system, but re-using the barcode scanners and other components from a non-working system supplied by others. |
Automotive |
West Midlands |
| Supply, installation and commissioning of OPsCon Server & iFIX Software and OPsCon Operator's Keyboard. |
Energy from Waste |
West Midlands |
| Supply of refurbished ABB/Bailey INICT01 + 2nd User INNIS01 |
Energy from Waste |
West Midlands |
| DeltaV systems engineering and configuration services for large pharmaceuticals project. |
Pharmaceutical |
East Midlands |
| Relocation, reconfiguration (including software enhancements), installation and commissioning of assembly line barcode monitoring system, comprising Data Logic barcode scanners, Allen-Bradley PLC and Intellution iFIX SCADA system. |
Automotive |
West Midlands |
| Supply, installation and commissioning of OPsCon/iFIX Client software and OPsCon operator's keyboards. |
Energy from Waste |
West Midlands |
| Engineering, assembly and commissioning of Emerson DeltaV-based tank level monitoring system to replace ageing Tankmaster 2000 including hazardous area mounted operator workstation, remote input/output cabinet and redundant fibre optic network. |
Specialty Chemicals |
North Wales |
| Siemens APACS/Intellution Fix32 software support services. |
Food & Beverage |
North West |
| Supply, configuration and commissioning of MTL MOST/Intellution iFIX-based distributed control system for general chemicals plant, including plant-based control cabinet located in Zone 2 hazardous area. |
Specialty Chemicals |
West Midlands |
| Configuration and commissioning of Emerson DeltaV DCS for batch chemicals plant. |
Specialty Chemicals |
West Midlands |
| Commissioning support for Bailey I90 DCS which had been relocated to control a new process plant. |
Lithographic |
North East |
| Upgrade of redundant Intellution iFIX servers, including the supply of 2 new client licenses and iGlobalcare support contract. |
Energy from Waste |
West Midlands |
| Preparation and presentation of customised training course for MTL MOST process control system and Intellution iFIX SCADA system. |
Specialty Chemicals |
West Midlands |
| Supply, configuration and commissioning of MTL MOST/Intellution iFIX-based distributed control system for speciality chemicals plant, including plant-based control cabinet located in Zone 2 hazardous area. |
Specialty Chemicals |
West Midlands |
| Upgrade of Bailey I90 console configuration to cater for EU Waste Incineration Directive, including specification and configuration of OPC interface to new Selective Non-Catalytic Reduction Plant. |
Energy from Waste |
West Midlands |
| Design review, validation and testing of Emerson DeltaV replacement control system for filtration and drying plant. |
Specialty Chemicals |
North Wales |
| Configuration and commissioning of Bailey I90 DCS/Conductor NT console system to accommodate new Selective Non-Catalytic Reduction Plant. |
Cement |
East Midlands |
| Configuration and commissioning of Bailey I90 DCS/Conductor NT console system to accommodate upgrade to kiln firing system. |
Cement |
East Midlands |
| Engineering support services and supply of spare parts for Emerson RS3 DCS, ABB I90 DCS and other process control equipment, including new project design, engineering and commissioning services. |
Oil & Gas |
East Anglia |